DateCityStateEmployerBody PartEvent
2020-09-09ClymanWiSENECA FOODS CORPFinger(s), fingernail(s)Caught in running equipment or machinery during maintenance, cleaning
An employee was setting up a canning line to package sliced beets. While checking to see if any food was stuck from sanitation, the employee's index finger contacted the rotating metal vanes of the rotary valve resulting in amputation.
2018-06-25ClymanWisconsinSeneca FoodsTrunkContact with hot objects or substances
An employee opened the inspection lid of a tank to see if the water in it was boiling. Hot water splashed out, causing second- and some third-degree burns to his torso.